Digi DC-190 Installationshandbuch

Stöbern Sie online oder laden Sie Installationshandbuch nach Küchenwaage Digi DC-190 herunter. Digi DC-190 Installation manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 67
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
74634
DC-190
ULTRA COUNT
Counting Scale
Version 4.0
Installation Manual
Seitenansicht 0
1 2 3 4 5 6 ... 66 67

Inhaltsverzeichnis

Seite 1 - Installation Manual

74634 DC-190 ULTRA COUNT Counting Scale Version 4.0 Installation Manual

Seite 2

6 DC-190 Ultra Count Installation Manual 2.0 Installation This section describes the procedure for theinstallation and setup of the DC-190 counting s

Seite 3 - Contents

Installation 7 2.3 Powering Up the DC-190The DC-190 can be operated either from an AC powersource or with an optional rechargeable battery pack(DC po

Seite 4

8 DC-190 Ultra Count Installation Manual5. Place scale on side. Remove four top coverscrews (shown in Figure 2-7). Set scale onlegs and remove top cov

Seite 5 - 1.0 Introduction

Installation 92.5 Installing Cable Strain ReliefTo prevent load cell or peripheral cable damage frombending and twisting, cable strain reliefs are us

Seite 6

10 DC-190 Ultra Count Installation Manual2.7 Load Cell ReplacementLoad cell replacement requires partial disassembly ofthe scale base. Sections 2.7.1

Seite 7

Installation 1114. Install power board using the four machinescrews previously removed. Route load cellcable under power board as shown inFigure 2-11.

Seite 8 - 1.4 DC-190 Console

12 DC-190 Ultra Count Installation Manual3.0 Scale SetupThis section provides information about attaching scales and serial devices to the DC-190. Inf

Seite 9 - 1.4.2 DC-190 Keypad

Scale Setup 13• The scale attached to Port 2 is configured as External Scale.• All Scales (1–4) must be configured, and the value of each bit pair must

Seite 10 - 2.0 Installation

14 DC-190 Ultra Count Installation Manual3.1.3 Scale Configurations, Including Force BalanceTable 3-2 lists several scale configurations for single, dua

Seite 11 - 2.3 Powering Up the DC-190

Scale Setup 153.2.1 Configuring SPEC 13SPEC 13 determines the type of data sent or received on the DIN-8 (FORCE BALANCE) and D-sub (232C/PRINTER) seria

Seite 13

16 DC-190 Ultra Count Installation Manual3.2.2 FORCE BALANCE (DIN-8) and 232C/PRINTER (D-Sub) Port ConnectionsTable 3-6 shows possible serial device c

Seite 14 - LOAD CELL CAP SCREWS

Configuration Settings 174.0 Configuration SettingsThis section presents the setup and configuration of the DC-190 counting scale to be used specifically

Seite 15 - BRACKETS

18 DC-190 Ultra Count Installation Manual4.2 Customer Specification (141 Settings)To configure customer specifications, press and hold the REZERO key and

Seite 16 - 3.0 Scale Setup

Configuration Settings 197 0000 Setpoint Buzzer0: Yes1: NoSetpoint Latch0: Latching1: Non-latchingSetpoint Type00: % Quantity 01: % Weight10: Quantity

Seite 17

20 DC-190 Ultra Count Installation Manual15 0011 RS-232C Stop Bits (Barcode pen)0: 1 Bit1: 2 BitsRS-232C with Header (Barcode pen)0: Yes (first charact

Seite 18 - 3.2 Serial Configurations

Configuration Settings 214.3 Weight and Measurement Specifications (142 Settings)To configure weight and measurement specifications, press and hold the

Seite 19

22 DC-190 Ultra Count Installation Manual27 0100 Comma Display0:No1:YesKeypad Entry of Tare0: No1: YesTare Range00: 100% FS 01: 50% FS10: 5% FS 11: No

Seite 20

Configuration Settings 2335 0000 Not used A/D Output (PORT 1, Scale 2)0: For std/normal load cell (≤ 18 mV)1: For abnormal load cell with too large of

Seite 21 - 4.0 Configuration Settings

24 DC-190 Ultra Count Installation Manual4.4 RS-232 Specifications (143 Settings)To configure RS-232 specifications, press and hold the REZERO key and e

Seite 22

Calibration 255.0 CalibrationThe calibration procedure maintains the scale accuracy within specifications and can serve as a performance testprocedure.

Seite 23 - * key (printer and PC)

© 2003 Rice Lake Weighing Systems. All rights reserved. Printed in the United States of America. Specifications subject to change without notice.Octob

Seite 24 - – Key in Add Mode

26 DC-190 Ultra Count Installation Manual6.0 Scale OperationsThe following sections contain detailed operator instructions for the DC-190 counting sca

Seite 25 - 142 access code

Scale Operations 276.2 Toggle Between ScalesTo switch the displays from Scale 1 through Scale 4, press the SCALE key when in weighing mode. Only scale

Seite 26

28 DC-190 Ultra Count Installation Manual6.4.2 Unit Weight Operation by Key EntryUnit weight operation by key entry is accomplished by using the numer

Seite 27 - Digital Tare with Weight

Scale Operations 29illuminated and the display shows the quantity of parts remaining.6. Remove a number of parts from the container and press the – ke

Seite 28

30 DC-190 Ultra Count Installation Manual7.0 Scale Programming7.1 Item Code StorageCode numbers allow you to store information for the parts that are

Seite 29 - 5.0 Calibration

Scale Programming 317.2 Item Code MaintenanceItem code maintenance includes viewing item codes in memory and deleting item memory.View Item Codes in M

Seite 30 - 6.0 Scale Operations

32 DC-190 Ultra Count Installation ManualNOTE: When you hear the beep, the display shows the last item code in memory. Press the – key to review theit

Seite 31 - 6.4 Entering Unit Weights

Scale Programming 33Re-Computing Item Code Unit Weight1. Recall item code from memory (see Section or Section ). 2. Place items to be counted on the

Seite 32

34 DC-190 Ultra Count Installation Manual7.4 Global Setpoint Programming– Setpoints Not Tied to an Item Code The DC-190 provides the flexibility to use

Seite 33 - 6.6 Other Operations

RS-232 Specifications 358.0 RS-232 Specifications8.1 RS-232 PortsThe DC-190 is equipped with three RS-232 ports for connecting devices such as a force

Seite 34 - 7.0 Scale Programming

ii DC-190 Ultra Count Installation Manual 7.0 Scale Programming...

Seite 35 - 7.2 Item Code Maintenance

36 DC-190 Ultra Count Installation Manual8.2 Eltron PrintersSee the Eltron printer manual for baud rate, data bit,and stop bit settings if it desired

Seite 36

RS-232 Specifications 378.3 Epson Tape PrintersThe Epson TM-U200 tape printer default settings(with and without cutter) are 9600 baud rate, eight-bitd

Seite 37

38 DC-190 Ultra Count Installation Manual8.4 Epson Ticket PrintersThe Epson TM-U295 ticket printer default settings are9600 baud rate, 8-bit data leng

Seite 38

RS-232 Specifications 398.6 PC Output Data Formats8.6.1 PC Output Data Format With HeaderThe DC-190-to-PC output data format (with header) isspecified

Seite 39 - 8.0 RS-232 Specifications

40 DC-190 Ultra Count Installation Manual8.6.2 PC Output Data Format Without HeaderThe DC-190-to-PC output data format (without header) is specified us

Seite 40 - 8.2 Eltron Printers

RS-232 Specifications 418.8 Status Data ByteThe status data byte for bits 0 through 7 is shownbelow. Status data byte will be set either to 1 or 0 inb

Seite 41 - 8.3 Epson Tape Printers

42 DC-190 Ultra Count Installation Manual8.9 Bar Code ScannersBar code scanning capabilities are available usingeither a laser scanner or a wand (or p

Seite 42 - 8.5 Digi BCP-300 Printer

RS-232 Specifications 438.11 Z CommandsZ command functions are usable when SPEC 14 andSPEC 15 are set as noted in the table below allowingas function

Seite 43 - 8.6 PC Output Data Formats

44 DC-190 Ultra Count Installation Manual9.0 PC Connections and Label FormattingTo connect the DC-190 Ultra Count to a PC for usewith the IMS invento

Seite 44 - SP SP SP SP SP SP SP SP SP CR

PC Connections and Label Formatting 459.1.4 Example of HyperTerminal DataFigure 9-3 shows an example of a HyperTerminaldisplay of data returned from a

Seite 45 - 8.8 Status Data Byte

Introduction 1 About This Manual This manual contains operating procedures for the DC-190 counting scale and provides the user with all theinformatio

Seite 46 - 8.10 Header

46 DC-190 Ultra Count Installation Manual9.2 Creating Labels for Eltron 2700-Series PrintersZebra Technologies’ Create-A-Label (CAL) software,supplied

Seite 47 - 8.11 Z Commands

PC Connections and Label Formatting 47To insert a header code for a linked field, enter theheader code value enclosed in quotation marks (forexample,

Seite 48 - 9.1 Using HyperTerminal

48 DC-190 Ultra Count Installation Manual9.2.3 Generating the EPL and EJF FilesWhen the label design is complete, save the label, thenselect Generate

Seite 49

PC Connections and Label Formatting 499.2.5 Downloading the EJF FileTo download the EJF file to the printer, install thedownload program, ELTRTERM.EXE

Seite 50

50 DC-190 Ultra Count Installation Manual10.0 AppendixThe following sections contain additional technical information for the DC-190 counting scale.10

Seite 51 - NET, OR TARE WEIGHT FIELDS

Appendix 5110.2 Scale Capacity and Display ResolutionThe weight display resolution of a scale can bedetermined by dividing the scale capacity by thedi

Seite 52

52 DC-190 Ultra Count Installation Manual10.3 Connector PinoutsThe DC-190 provides CTS/RTS hardware handshaking lines on both the 8-pin DIN and 9-pin

Seite 53

Appendix 53Figure 10-5 shows how the DC-190 can be attached to output relays for setpoint control of external equipment.Components shown include a fou

Seite 54 - 10.0 Appendix

54 DC-190 Ultra Count Installation Manual10.4 Cable WiringThe following tables show wiring specifications for cables used with the Epson TM-U295/TM-U20

Seite 55

Appendix 5510.5 Y-Cable Wiring DiagramFigure 10-6 shows a wiring diagram for the Y-cable used to attach a separate remote platform as interna.l scale

Seite 56 - 10.3 Connector Pinouts

2 DC-190 Ultra Count Installation Manual 1.1 Unpacking and Inspection Immediately after unpacking, visually inspect the DC-190 Ultra Count to ensure

Seite 57 - POWER SUPPLY

56 DC-190 Ultra Count Installation Manual10.6 DC-190 MessagesMessage ContentsACC Accuracy---Add XX Sampling quantity is insufficientALL All memoryC X

Seite 58 - 10.4 Cable Wiring

Appendix 5710.7 Clearing Locked-Up Scale (888888 Error)Several configuration errors can result in the scale locking up with a display that shows all 88

Seite 59 - 10.5 Y-Cable Wiring Diagram

58 DC-190 Ultra Count Installation Manual10.8 DC-190 Character Code List (Teraoka Code)The DC-190 is not equipped with a full alphanumeric keyboard, b

Seite 60 - 10.6 DC-190 Messages

Appendix 5910.9 Bar Code Board

Seite 61

60 DC-190 Ultra Count Installation Manual10.10 PSC QuickScan 6000 SetupFigures 10-7 and 10-8 (see page 61) provide setup scans for the PSC® QuickScan®

Seite 62

Appendix 61Figure 10-8. Scan Sheet for PSC QuickScan 6000 (Part 2)SCAN SETSCAN SETSCAN ENDSCAN ENDSET SUFFIXSUFFIX DSUFFIX 0DISABLE I.D. CONTROLSCAN S

Seite 63 - 10.9 Bar Code Board

62 DC-190 Ultra Count Installation Manual10.11 DC-190 Ultra Count SpecificationsPowerPower source 100–120VAC or 220–240 VAC at 50/60 HzPower consumptio

Seite 64 - 15 in Table 4-1 on page 50

Appendix 63DC-190 Ultra Count Limited WarrantyRice Lake Weighing Systems (RLWS) warrants that all RLWS equipment and systems properly installed by aDi

Seite 65 - Appendix 61

Introduction 3 ModelCapacity (lb) Weighing Resolution (lb) Internal Resolution (lb) Platform DimensionsS-SL-50 50 0.005 0.00005 13” x 17”S-SL-100 100

Seite 66

4 DC-190 Ultra Count Installation Manual 1.4 DC-190 Console Figure 1-1 shows the DC-190 console with annunciators and numeric keypad. Annunciators ar

Seite 67 - Appendix 63

Introduction 5 1.4.2 DC-190 Keypad Table 1-5 lists the keys and key functions of the DC-190 Ultra Count keypad (see Figure 1-1 on page 4). KeyDescrip

Kommentare zu diesen Handbüchern

Keine Kommentare