Digi DC-100 Spezifikationen

Stöbern Sie online oder laden Sie Spezifikationen nach Küchenwaage Digi DC-100 herunter. Digi DC-100 Specifications Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken

Inhaltsverzeichnis

Seite 1 - Operation Manual

109429DC-782 Counting ScaleOperation ManualCounting ScaleVersion 1.006

Seite 2

6 DC-782 Operation ManualFigure 2-1. Leveling Bubble2.4 Powering Up the DC-782The DC-782 can be operated either from an AC power source or with a rech

Seite 3 - Contents

Installation 74. Once the scale is on, the time interval before the scale will automatically power itself off, if there no key is pressed and no weigh

Seite 4

8 DC-782 Operation Manualgoing into the normal weighing mode.• If SPEC 20, Bit 2 is set to 1: Standard, the scale’s display will test the LCD segments

Seite 5 - 1.0 Introduction

Installation 92.5 Replacement PartsThe following list contains the part numbers and descriptions of replacement parts available for the DC-782 countin

Seite 6 - 1.3 Keyboard and Display

10 DC-782 Operation Manual2.6 Block Diagram of Electrical ConnectionsThe following block diagram illustrates the electrical connections.

Seite 7 - Figure 1-2. Key Sheet Layout

Installation 112.7 Physical Layout of Electrical ConnectionsThe following diagram illustrates the actual layout of the electrical connections.

Seite 8

12 DC-782 Operation Manual3.0 Configuration SettingsThis section presents the setup and configuration of the DC-782 counting scale to be used specific

Seite 9 - 2.0 Installation

Configuration Settings 13If this is the SPEC that you want to modify, enter the new setting from the numeric keypad and press the * CONFIRM key to ent

Seite 10 - Leveling

14 DC-782 Operation Manual3.2.2 Weight and Measurement Specifications (142 Settings)To make changes to the Weight and Measurement Specifications, the

Seite 11 - Installation 7

Configuration Settings 153. To change another SPEC code before exiting, repeat Steps 1 and 2.4. To save all the changed SPEC settings currently in tem

Seite 13 - 2.5 Replacement Parts

16 DC-782 Operation Manual27 Ta re Auto Cl e a r0: Allow1: Inhibit (DEFAULT)Unit Weight Auto Clear0: .Allow1: Inhibit (DEFAULT)Auto Clear Condition0:

Seite 14 - 10 DC-782 Operation Manual

Calibration 174.0 CalibrationThe DC-782 scale is a high-precision instrument. Although the scale needs very little maintenance, you may want to check

Seite 15 - Installation 11

18 DC-782 Operation Manual3. The scale display will confirm that you are in the Calibration Mode. 4. Make sure that there is no weight on the platform

Seite 16 - 3.0 Configuration Settings

Scale Operations 195.0 Scale OperationsThe following sections contain detailed operator instructions for the DC-782 counting scale (see Figure 5-1). I

Seite 17

20 DC-782 Operation ManualNote: The following SPEC codes must be set properly to allow these operations before continuing: SPEC 25, Bit 3 - MANUAL TAR

Seite 18

Scale Operations 21Example: A sample of 10 zener diodes is placed on the scale. The Unit Weight is computed by the scale to be 0.0006536 lbs. However,

Seite 19

22 DC-782 Operation Manual5.4 Operations Without Recalling an Item CodeThe following sections describe ways to carry out operations without having to

Seite 20

Scale Operations 237. Continue with the remainder of the containers to be counted. The total number of parts stored in all the containers will be stor

Seite 21 - 4.0 Calibration

24 DC-782 Operation Manual4. If at the end of the procedure, if you want to see how many remain in the bin or container, you first have to know the ta

Seite 22 - 18 DC-782 Operation Manual

Scale Programming 256.0 Scale ProgrammingThe DC-782 can store information for the parts you count most frequently, eliminating the need for re-enterin

Seite 23 - 5.0 Scale Operations

iContentsAbout This Manual ...

Seite 24 - 5.3 Entering Unit Weights

26 DC-782 Operation Manualto exit the Programming Mode. To change the previously entered data in any field, enter it from the keypad or, in the case o

Seite 25 - PIECES key again. The scale

Scale Programming 276.3 Program a General SetpointYou can program the DC-782 with a setpoint that will be enabled either when no Item Code is called u

Seite 26

28 DC-782 Operation Manual6.5 Delete Item MemoryThe DC-782 allows you to delete individual items from memory.The following procedure describes the ste

Seite 27 - 5.4.2.2 Negative Counting

RS-232C Communication with PC 297.0 RS-232C Communication with PCThe DC-782 Counting Scale is equipped with an RS-232C port that allows the scale to s

Seite 28 - 5.5.2 Delete Item Memory

30 DC-782 Operation Manual7.4 Communication MethodSPEC10-RS-232C PC Protocol configures whether the data transfer to the computer is inhibited (0000:

Seite 29 - 6.0 Scale Programming

RS-232C Communication with PC 317.4.2 Standard Manual Data TransmissionSet SPEC10-RS-232C PC Protocol to 0010: Standard Manual Type. The communicatio

Seite 30 - Table 6-3. Setpoint Examples

32 DC-782 Operation Manual7.4.3 Standard Command Data TransmissionSet SPEC10-RS-232C PC Protocol to 0011: Standard Command Type. The data transmission

Seite 31 - 6.4 Programming a Preset Key

RS-232C Communication with PC 337.6 RS-232C Data Transmission FormatsThe basic data transmission string format output by the DC-782 is as follows (wit

Seite 32 - 6.5 Delete Item Memory

34 DC-782 Operation ManualWeight Condition Flag:Bit 7: Not used; always set to zeroBit 6: Fixed to 1Bit 5: Not usedBit 4: Weight UF - 0: when no weigh

Seite 33 - 7.1 Connection

RS-232C Communication with PC 35Data Transmission ExamplesExample 1:If the following are true: Net Weight = 3.400 lbTare Weight = 1.200 lbUnit Weight

Seite 34 - 7.4 Communication Method

ii DC-782 Operation Manual6.3 Program a General Setpoint . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Seite 35

36 DC-782 Operation ManualExample 3:In this example there is a weight overflow and only the status, weight condition flag and net weight are transmitt

Seite 36

Appendix 378.0 Appendix8.1 DC-782 SpecificationsOperating Conditions• Power Source - AC117/100V• Operating Temperature- -10°C ~ +40°C (OIML)• Operatin

Seite 37

38 DC-782 Operation Manual8.2 DC-782 Error Message ListThe DC-782’s alphanumeric display allows for detailed error messages. Use Table 8-1 below to fi

Seite 38

DC-782 Limited Warranty 399.0 DC-782 Limited WarrantyRice Lake Weighing Systems (RLWS) warrants that all RLWS equipment and systems properly installed

Seite 39

Introduction 1About This ManualThis manual contains operating procedures for the DC-782 counting scale and provides the user with all the information

Seite 40 - Example 3:

2 DC-782 Operation Manual1.3 Keyboard and DisplayFigure 1-1 shows the DC-782 console with its indicator lamps, the function keyboard and the numeric k

Seite 41 - 8.0 Appendix

Introduction 31.3.3 Key FunctionsThe DC-782 features many functions for managing inventory information and scale operation. Figure 1-2 shows the key-s

Seite 42 - 8.2 DC-782 Error Message List

4 DC-782 Operation Manual+ (Plus) key.Weighing Mode - Used to accumulate data. Also prompts outputting of data to a PC if one is connected.Programmin

Seite 43 - 9.0 DC-782 Limited Warranty

Installation 52.0 InstallationThis section describes the procedure for the installation and setup of the DC-782 counting scale.2.1 UnpackingDo not tur

Kommentare zu diesen Handbüchern

Keine Kommentare

Niles Audio Les dispositifs de saisie manuels d'utilisation

À partir de S

Cliquez sur un alphabet ci-dessous pour faire défiler la liste complète des modèles commençant par cette lettre

Modèles Type de document
SYMPTOM SI-2125
Manuel de l'utilisateur   Niles Audio SYMPTOM SI-2125 User Manual, 20 pages