TCP settings
The TCP Settings are displayed only when the current serial port is configured with the TCP
Sockets or the Custom Profile. The settings are as follows:
Send Socket ID: Include an optional identifier string with the data sent over the network. The
Socket ID can be 1 to 256 ASCII characters. To enter non-printable characters, use these key
sequences:
Character
Key Sequence
backspace
\b
formfeed
\f
tab
\t
new line
\n
return
\r
backlash
\\
hexadecimal values
\xhh
Send data only under any of the following conditions: Enable if it is required to set
conditions on whether the ConnectPort LTS product sends the data read from the serial port to
the TCP destination. Conditions include:
Send when data is present on the serial line: Send the data to the network destinations
when a specific string of characters is detected in the serial data. Enter the string 1 to 4
characters in the Match String field. To enter non-printable characters, use these key
sequences:
Character
Key Sequence
hexadecimal values
\xhh
tab
\t
linefeed
\n
backspace
\b
Strip match string before sending: Match string before sending to strip the string from
the data before it is sent to the destination.