Digi Digi One EM Installationsanleitung Seite 117

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 168
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 116
set serial
Chapter 2 Command Descriptions 117
csize={5|6|7|8}
The character size, which can be 5, 6, 7, or 8 bits. The default is 8.
flowcontrol={hardware|software|none}
Specifies which kind of flow control is used on the line.
hardware
Hardware flow control (RTS/CTS).
software
Software flow control (Xon/Xoff).
none
No flow control.
The default is “software.”
parity={none|even|odd|mark|space}
The parity used for the line.
none
No parity.
even
Even parity.
odd
Odd parity.
mark
Mark parity.
space
Space parity.
The default is “none.”
stopb={1|2}
The number of stop bits per character to use on this line. The value used
here must match the setting on the device connected to this port. Use 1
or 2 stop bits.
The default is 1 stop bit.
Example set serial baudrate=9600 flowcontrol=hardware
See also "revert" on page 39.
Seitenansicht 116
1 2 ... 112 113 114 115 116 117 118 119 120 121 122 ... 167 168

Kommentare zu diesen Handbüchern

Keine Kommentare